DocumentCode :
110119
Title :
DOA-Based Endoscopy Capsule Localization and Orientation Estimation via Unscented Kalman Filter
Author :
Shu Ting Goh ; Reza Zekavat, Seyed A. ; Pahlavan, Kaveh
Author_Institution :
Sch. of Electr. & Electron. Eng., Nanyang Technol. Univ., Singapore, Singapore
Volume :
14
Issue :
11
fYear :
2014
fDate :
Nov. 2014
Firstpage :
3819
Lastpage :
3829
Abstract :
The endoscopy capsule is a medical device capable of capturing images inside human´s digestion system, specifically the small and big intestine. For medical diagnostics and surgery, it is required to know the position and direction of the image taken inside digestion system. This paper considers an alternative method of presurgery gastroscopy and colonoscopy monitoring procedure that allows the patient to freely move inside the medical ward. The direction-of-arrival (DOA) and inertial measurement unit (IMU) measurements are integrated to track the movement of capsule with respect to patient´s body reference frame. The DOA is estimated via antenna arrays installed within a medical ward and the IMU is installed on the capsule endoscopy. The IMU sends the position information wirelessly to the antenna arrays in medical ward. Additional beacons are attached to the patient to allow body orientation and absolute position estimation due to the free movement. The nonhomogeneous nature of human body refracts the signal transmitted by the capsule, which leads to a highly nonlinear DOA function. This paper implements the unscented Kalman filter (UKF) to track the capsule by fusing the measurements made by DOA, IMU, and additional beacons attached to the patient. Simulations are conducted to investigate the capsule tracking and orientation estimation performance with respect to DOA resolution and beacons localization accuracy. Results confirm that compared with the DOA resolution, the beacons localization accuracy has a higher impact on the capsule orientation estimation performance. Furthermore, this paper investigates the impact of the number of available antenna arrays on multiplication required by UKF.
Keywords :
Kalman filters; antenna arrays; body sensor networks; direction-of-arrival estimation; endoscopes; medical signal processing; patient monitoring; DOA resolution; DOA-based endoscopy capsule localization; IMU measurements; UKF; absolute position estimation; antenna arrays; beacons localization accuracy; body orientation estimation; capsule tracking; colonoscopy monitoring procedure; direction-of-arrival estimation; endoscopy capsule orientation estimation; inertial measurement unit; medical ward; nonlinear DOA function; patient body reference frame; presurgery gastroscopy; unscented Kalman filter; Accuracy; Antenna arrays; Direction-of-arrival estimation; Estimation; Sensor arrays; Vectors; Kalman filters; body sensor networks; capsule endoscopy; directional-of-arrival;
fLanguage :
English
Journal_Title :
Sensors Journal, IEEE
Publisher :
ieee
ISSN :
1530-437X
Type :
jour
DOI :
10.1109/JSEN.2014.2342720
Filename :
6866119
Link To Document :
بازگشت