DocumentCode :
1102070
Title :
Heterodyne radiometry measurements of the 557 GHz H2O rotational line
Author :
Dionne, Gerald F. ; Fetterman, Harold R. ; Erickson, Neal R. ; Parker, Christopher D. ; Fitzgerald, James F.
Author_Institution :
Lincoln Lab, M.I.T., Lexington, MA, USA
Volume :
20
Issue :
3
fYear :
1984
fDate :
3/1/1984 12:00:00 AM
Firstpage :
188
Lastpage :
190
Abstract :
A high-resolution heterodyne radiometer that utilizes a crossed-guide harmonic mixer pumped by a 300 GHz carcinotron as a local oscillator has been developed for submillimeter wavelengths. Previous investigations of the radiation transfer properties of spectral lines in supersonic gas flow have been extended to longer wavelengths using the tunability of this system. With less than 2 mW of fundamental local oscillator power, traces of the 557 GHz ortho-H2O rotational transition ( 1_{10} \\leftarrow 1_{01} ), Doppler-broadened to only a few MHz, were observed in absorption against a continuum background.
Keywords :
Submillimeter-wave radiometry; Extraterrestrial measurements; Filtering; Fluid flow; Frequency measurement; Local oscillators; Power harmonic filters; Radiometry; Schottky diodes; Temperature sensors; Tunable circuits and devices;
fLanguage :
English
Journal_Title :
Quantum Electronics, IEEE Journal of
Publisher :
ieee
ISSN :
0018-9197
Type :
jour
DOI :
10.1109/JQE.1984.1072389