Title :
Modified method of high alternating current measurement
Author :
Bera, S.C. ; Kole, D.N. ; Mandal, M.
Author_Institution :
Dept. of Appl. Phys., Univ. of Calcutta, Kolkata
fDate :
5/1/2008 12:00:00 AM
Abstract :
The conventional current transformers (CTs) in the form of a bar primary and secondary winding on a highly permeable ring core suffer from ratio error and phase angle errors, which are primarily due to the no-load current of the transformer. A modified design of a CT has been described. In this design, a feedback technique has been used in order to reduce the no-load current to a negligibly small value so that the said error may be minimal. Using this technique, a CT has been designed and fabricated with the commercially available material. The performance of the transformer has been tested experimentally and the output and input AC waves have been observed in a storage cathode ray oscilloscope (CRO) and the experimental results are reported.
Keywords :
current transformers; electric current measurement; transformer windings; CRO; CT; alternating current measurement; cathode ray oscilloscope; conventional current transformers; feedback technique; no-load current; permeable ring core; phase angle errors; ratio error; transformer windings;
Journal_Title :
Science, Measurement & Technology, IET
DOI :
10.1049/iet-smt:20070029