DocumentCode
1103807
Title
Advantages and disadvantages of embedment to prevent external mechanical damages to submarine cables
Author
Arnaud, U. ; Bazzi, G. ; Valenza, D.
Author_Institution
Societa Cavi Pirelli, Milan, Italy
Volume
5
Issue
1
fYear
1990
fDate
1/1/1990 12:00:00 AM
Firstpage
54
Lastpage
57
Abstract
The CIGRE paper `Methods to Prevent Mechanical Damage to Submarine Cables´ (1986) deals with failures in submarine cable links. However, it does not deal with power transmission availability. Furthermore, it may give the impression that total embedment is recommended. The authors argue that this is much too expensive and might endanger the economic viability of a cable solution. A definition of power availability is given. The importance of spare cables is stressed. After a review of the cable protection methods, some examples of power availability in existing submarine cable links are given. The authors also state that, in order to optimize the cost of protection, new guidelines need to be developed. A CIGRE working group has been set up to accomplish this task
Keywords
power cables; submarine cables; cable protection methods; embedment; external mechanical damage prevention; power availability; submarine cables; Availability; Circuits; Cost function; Guidelines; Mechanical cables; Power generation economics; Power transmission; Protection; Samarium; Underwater cables;
fLanguage
English
Journal_Title
Power Delivery, IEEE Transactions on
Publisher
ieee
ISSN
0885-8977
Type
jour
DOI
10.1109/61.107255
Filename
107255
Link To Document