DocumentCode :
1104178
Title :
The Effect of Mutual Inductance and Mutual Capacitance on the Transient Response of Braided-Shield Coaxial Cables
Author :
Merewether, David E. ; Ezell, T. Frank
Author_Institution :
Mission Research Corporation, Albuquerque, NM 87108
Issue :
1
fYear :
1976
Firstpage :
15
Lastpage :
20
Abstract :
A quantitative comparison is made of the importance of mutual inductance and mutual capacitance in the leakage of transient signals through the braid of a coaxial cable. The difference between mutual inductance and mutual capacitance coupling is vividly exhibited in the transient predictions. Comparisons of predictions to measurements made on a length of RG-214 test cable are also included.
Keywords :
Cable shielding; Capacitance; Circuits; Coaxial cables; Electrical resistance measurement; Impedance measurement; Inductance; Length measurement; Mutual coupling; Transient response;