• DocumentCode
    1104461
  • Title

    Coupling currents losses bench mark test of ITER subsize conductor

  • Author

    Bruzzone, Pierluigi ; Gung, Chen-Yu ; Meuris, Chantal ; Ten Kate, Herman H J

  • Author_Institution
    Max-Planck-Inst. fur Plasmaphys., Garching bei Munchen, Germany
  • Volume
    32
  • Issue
    4
  • fYear
    1996
  • fDate
    7/1/1996 12:00:00 AM
  • Firstpage
    2826
  • Lastpage
    2829
  • Abstract
    To solve the discrepancies frequently observed between coupling currents losses results measured on similar samples at different labs, a bench merit test action has been carried out among five laboratories of the four partners of the ITER project. The specimen for the bench mark action is a short sections of Nb3Sn cable-in-conduit conductor with the same layout as the last but one stage of the ITER conductor. The five labs measure the AC losses by boil-off calorimetry. The test programme, selected according to the capabilities of the test equipment, allows a direct comparison of the test results over a broad range of field pulses
  • Keywords
    critical current density (superconductivity); eddy current losses; fusion reactor materials; losses; niobium alloys; superconducting coils; superconducting magnets; superconducting materials; tin alloys; ITER subsize conductor; Nb3Sn; Nb3Sn cable-in-conduit conductor; bench merit test action; boil-off calorimetry; coupling currents losses bench mark test; field pulses; Cable shielding; Conductors; Furnaces; Heat treatment; Loss measurement; Niobium-tin; Plasmas; Superconducting cables; Surface resistance; Testing;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.511463
  • Filename
    511463