Title : 
On the Effective Transfer Impedance of Thin Coaxial Cable Shields
         
        
            Author : 
Casey, Kendall F.
         
        
            Author_Institution : 
Department of Electrical Engineering, Kansas State University, Manhattan, KS 66506
         
        
        
        
        
        
            Abstract : 
It is shown that the effective transfer impedance per unit length of a thin coaxial cable shield is given by Zs h2/Ys, where ZS and Ys are, respectively, the cable´s inductive transfer impedance per unit length and capacitive transfer admittance per unit length, and h is the axial propagation constant. This general result is illustrated by consideration of a specific shield model, the M-filar filamentary helix.
         
        
            Keywords : 
Admittance; Cable shielding; Coaxial cables; Communication cables; Conductors; Equations; Impedance; Propagation constant; Transmission lines; Voltage;
         
        
        
            Journal_Title : 
Electromagnetic Compatibility, IEEE Transactions on
         
        
        
        
        
            DOI : 
10.1109/TEMC.1976.303480