    Submicrometer CMOS device fabrication using an X-ray stepper

  • Author

    Suzuki, K. ; Okada, K. ; Matsui, J. ; Endo, N. ; Iida, Y. ; Fukuma, M.

  • Author_Institution
    NEC Corporation, Kawasaki, Japan
  • Volume
    6
  • Issue
    7
  • fYear
    1985
  • fDate
    7/1/1985 12:00:00 AM
  • Firstpage
    353
  • Lastpage
    355
  • Abstract
    CMOS devices with submicrometer minimum features have been fabricated using X-ray/photo hybrid lithography. The device fabrication process utilized thirteen lithography steps, including four X-ray lithography levels, such as local oxidation of silicon (LOCOS) [1], gate, contact, and wiring, that required the most critical dimension control and alignment accuracy. A step and repeat exposure system and a SiNxmembrane mask were used for the X-ray lithography process. The SiNxmembrane mask was improved in its flatness and effective contrast by employing a stress compensating structure and a secondary electron trapping film. As a result, CMOS devices with 0.4-µm effective channel length were fabricated using a single-layer resist process.