DocumentCode :
1106293
Title :
Coil protection for the 20.4 MWh SMES/ETM
Author :
Loyd, R.J. ; Bulc, A.M. ; Chang, C.L.
Author_Institution :
Bechtel Group Inc., San Francisco, CA, USA
Volume :
27
Issue :
2
fYear :
1991
fDate :
3/1/1991 12:00:00 AM
Firstpage :
1716
Lastpage :
1719
Abstract :
The 20.4-MWh superconducting magnetic energy storage engineering test model (SMES/ETM) is large and stores nearly two orders of magnitude more energy than any man-made magnet to date. These characteristics pose unique requirements for coil protection in response to a normal zone. A method of detecting a normal zone, action taken to quench the coil, and the subsequent temperature and voltage response of the coil pack are presented. It is shown that a normal zone produces a significant resistive voltage that can be easily detected, the coil is driven normal at half-turn intervals by inductive heaters, and coil response is calculated to be benign, both thermally and electrically
Keywords :
protection; superconducting magnet energy storage; 20.4 MWh; SMES/ETM; coil protection; coil response; engineering test model; normal zone; resistive voltage; superconducting magnetic energy storage; Power engineering and energy; Protection; Resistance heating; Samarium; Superconducting coils; Superconducting magnetic energy storage; Temperature; Testing; Thermal resistance; Voltage;