Abstract :
The production of high-gradient superconducting quadrupoles for the Tevatron D0/B0 low-beta insertion is currently underway. The two-shell design utilizes a 36-strand Rutherford-style cable. A measure of cable quality is given by a comparison of the critical current of the cable with the sum of the critical currents of the strand. A recent study involving variations in the cabling conditions and dimensional parameters has resulted in a significant decrease in degradation. Over the period of cable production degradation has been reduced from an average 12% to less than 4%. Some cable samples measured exhibit J c´s in excess of 3100 A/mm2 at 5 T. The adjustments to the cabling procedure which are believed to be responsible for the reduction in Jc degradation are discussed
Keywords :
beam handling equipment; composite superconductors; critical current density (superconductivity); critical currents; proton accelerators; storage rings; superconducting cables; superconducting magnets; synchrotrons; 5 T; Fermilab low beta quadrupole cable; Rutherford-style cable; Tevatron D0/B0 low-beta insertion; cabling procedure; critical current density; critical currents; degradation; high-gradient superconducting quadrupoles; two-shell design; Conductors; Critical current; Critical current density; Current measurement; Degradation; Laboratories; Production; Superconducting cables; Superconducting coils; Superconducting magnets;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.133546
Filename :
133546
Link To Document :
بازگشت