• DocumentCode
    1107810
  • Title

    Radio Frequency Response of a Large Turbine-Generator Stator Winding

  • Author

    Emery, F.T. ; Harrold, R.T.

  • Author_Institution
    Westinghouse Electric Corporation, Steam Turbine Generator Division, Orlando, Florida 32817
  • Issue
    2
  • fYear
    1986
  • fDate
    6/1/1986 12:00:00 AM
  • Firstpage
    172
  • Lastpage
    179
  • Abstract
    Long term experience with on-line radio frequency monitoring of large turbine generators has shown a need for increased understanding of the propagation of arc generated radio frequency signals in a stator winding. This paper presents the results of an on going research program designed to obtain an increased understanding of radio frequency arc detection in large turbine generators. Test results from AC arcing response and sinewave response measurements made on a generator stator are presented in addition to the results obtained from a computer circuit analysis performed on a radio frequency circuit model of a portion of the same generator stator. These results led to a better understanding of RF arc signal propagation and helped to identify improved detection techniques. Three RF measurement techniques were studied for both the measurements and calculations, resulting in good agreement. Arc voltage detection sensitivity calculations give a minimum detectable level of arc voltage for each RF measurement technique.
  • Keywords
    AC generators; Circuit analysis computing; Circuit testing; Measurement techniques; RF signals; Radio frequency; Signal generators; Stator windings; Turbines; Voltage;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/TEC.1986.4765717
  • Filename
    4765717