Abstract
many permanent magnet synchronous motors are run up from standstill by a sudden connection with an ac supply. The cage windings in rotor slots produce induction motor torque to run up the rotor, but two torque dips are produced in the torque-slip curve of the permanent magnet motor; one is caused by the rotating permanent magnet, and the other by the magnetic and the electric asymmetry between the direct and quadrature axes. Therefore, the prediction of the asynchronous performance is very important, as motors cannot be run up, unless the minimum values of the torque dips exceed the load torques at the slips. In this paper, ``harmonic permeance coefficient´´ is newly introduced, which is used to combine the finite element field solution with the calculation of air gap inductance, and equations for the calculation of asynchronous performance of permanent magnet motors are also expressed. The calculated value by these equations agreed well with the experimental results.
Keywords
Equations; Frequency; Inductance; Induction motors; Magnetic flux; Permanent magnet motors; Rotors; Synchronous motors; Torque; Voltage;