Title :
A high-resolution color CRT for CAD/CAM use
Author :
Nakanishi, Hisao ; Okuda, Souitirou ; Yoshida, Tadahisa ; Sugahara, Takashi
Author_Institution :
Mitsubishi Electric Corporation, Nagaokakyo, Kyoto, Japan
fDate :
8/1/1986 12:00:00 AM
Abstract :
A 19-V color CRT with 64-kHz scanning was developed for CAD/CAM use. A new gun was designed by a three-dimensional phase space method and with the aid of a three-dimensional beam tracing computer simulation. A newly developed oxide cathode was applied to the gun in order to improve the life performance of cathode emission. The spot size at 2 percent of peak was reduced to 0.8 mm at 200 µA. A significant reduction of misconvergence to 0.2 mm was achieved through the use of a small beam-to-beam gun spacing, a new deflection yoke, and a new frittable getter.
Keywords :
Apertures; CADCAM; Cathode ray tubes; Computer aided manufacturing; Computer simulation; Design automation; Electrodes; Electron beams; Lenses; Structural beams;
Journal_Title :
Electron Devices, IEEE Transactions on
DOI :
10.1109/T-ED.1986.22631