• DocumentCode
    1109966
  • Title

    A Comparison of the Currents Induced on an EUT in a TEM Cell to Those Induced in a Free-Space Environment

  • Author

    Fornberg, Per E. ; Holloway, Christopher L.

  • Author_Institution
    Intel Corp., Hillsboro
  • Volume
    49
  • Issue
    3
  • fYear
    2007
  • Firstpage
    474
  • Lastpage
    484
  • Abstract
    The finite-difference time-domain method is used to investigate whether the currents induced on equipment under test (EUT) in a transverse electromagnetic (TEM) cell are similar to those induced in a free-space environment. The approach is to simulate an identical EUT in both environments and determine a correlation based on the respective current distributions. The effect of the ratio of EUT to TEM cell sizes on the correlation to free space is also investigated. This paper introduces a metric that quantifies the change in the surface current induced on the EUT in these different environments.
  • Keywords
    TEM cells; finite difference time-domain analysis; testing; EUT; TEM Cell; current distributions; equipment under test; finite-difference time-domain method; free-space environment; transverse electromagnetic cell; Current density; Current distribution; Electromagnetic compatibility; Finite difference methods; Integral equations; Numerical simulation; TEM cells; Testing; Time domain analysis; Transmission lines; Equipment under test (EUT); induced current; numerical simulation; transverse electromagnetic (TEM) cell;
  • fLanguage
    English
  • Journal_Title
    Electromagnetic Compatibility, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9375
  • Type

    jour

  • DOI
    10.1109/TEMC.2007.903036
  • Filename
    4295212