DocumentCode
1110372
Title
Mapping matrices against vectorial frame in the instantaneous reactive power compensation
Author
Salmeró, P. ; Herrera, R.S. ; Vázquez, J.R.
Author_Institution
Univ.of Huelva, Huelva
Volume
1
Issue
5
fYear
2007
Firstpage
727
Lastpage
736
Abstract
The original instantaneous reactive power or p-q theory has been used in a systematic way in the control of active power niters (APFs). When the APF is switched in parallel to a nonlinear and unbalanced load, the application of p-q theory allows a constant power compensation strategy. This means that after the APF connection, the supply instantaneous power is constant and presents the same value as the load average power. The use of other compensation strategies such as unity power factor, sinusoidal or balanced supply currents, among others, is also possible, as the development of another compensation strategy is possible within the p-q theory frame. A p-q theory reformulation without using mapping matrices is presented, which makes obtaining compensation currents easier. Finally, an exhaustive analysis of practical cases has been carried out at simulation and experimental levels through a laboratory prototype that has allowed verification of the proposed approach.
Keywords
active filters; power filters; reactive power; active power filters; constant power compensation; instantaneous reactive power compensation; mapping matrices; vectorial frame;
fLanguage
English
Journal_Title
Electric Power Applications, IET
Publisher
iet
ISSN
1751-8660
Type
jour
DOI
10.1049/iet-epa:20060256
Filename
4295943
Link To Document