• DocumentCode
    1110452
  • Title

    LORAN-C Positioning Errors Caused by Scattering from Wires Above the Earth

  • Author

    Olsen, Robert G. ; Aburwein, Abdulmagid

  • Author_Institution
    Department of Electrical Engineering, Washington State University, Pullman, WA 99164. (509) 335-4950
  • Issue
    4
  • fYear
    1982
  • Firstpage
    381
  • Lastpage
    388
  • Abstract
    In this paper, the scattering of a LORAN-C navigation signal by a powerline is calculated. The results of the derivation can be used to predict positioning errors for land-based applications of LORAN-C, such as vehicle-location schemes. The only assumptions are that the line spacing is small compared to its height and that the LORAN-C signal is narrow band, and not incident at a grazing angle. From this general result, a very simple theory for predicting positioning errors is derived which is valid for most parameters of interest. It is found that, when a LORAN-C receiver is located near a powerline, position errors of 1 km are possible. This value is in accord with published experimental results. Further, it is shown that position errors are significantly greater when the LORAN-C signal approaches the transmission line at a small angle.
  • Keywords
    Conductors; Earth; Narrowband; Navigation; Power generation; Power transmission lines; Pulse measurements; Scattering; Transmission line theory; Wires; LORAN-C errors; Powerline scattering; positioning errors; vehicle location;
  • fLanguage
    English
  • Journal_Title
    Electromagnetic Compatibility, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9375
  • Type

    jour

  • DOI
    10.1109/TEMC.1982.304052
  • Filename
    4091587