Title :
Safety-Margin Measurements of Electroexplosives: DC-RF Power-Substitution Method
Author_Institution :
Quality Assurance Group of Transport Canada (a Federal Department), Ottawa, Canada KIA ON5. (613) 996-3757
Abstract :
Some of the indirect methods in current use for measuring the safety margins of installed electroexplosives are briefly reviewed. The basic requirements of the military specifications are indicated. A direct measurement of resistance variation versus dissipated power, on actual devices, is proposed as a better alternative. The method provides the capability of measuring unmodified real electroexplosives with some temperature coefficient, and also indicates a new utilization of SEM fuses and deactivated EED´s for quantitative measurements.
Keywords :
Aerospace safety; Electrical resistance measurement; Electromagnetic compatibility; Fuses; Instruments; Power measurement; Radio frequency; Scanning electron microscopy; Temperature measurement; Testing; Electroexplosive devices; RF safety margin; dc-RF power substitution; measurement technique;