Title
End Component of Armature Leakage Reactance of Turbine Generators
Author
Tegopoulos, J.A.
Author_Institution
Westinghouse Electric Corporation, East Pittsburgh, Pa.
Volume
83
Issue
6
fYear
1964
fDate
6/1/1964 12:00:00 AM
Firstpage
632
Lastpage
637
Abstract
Stator and rotor end windings are considered to be closed systems of currents, as the end coils are assumed to close through the air gap by means of fictitious filaments. The leakage reactance end component then is calculated on the basis of the net flux linking the stator end winding when both stator and rotor are excited with currents in such a way that the net flux density in the air gap is zero. All iron boundaries of the end-zone region are considered to be perfect magnetic receptors which contain no eddy currents.
Keywords
Eddy currents; Iron; Joining processes; Magnetic cores; Magnetic flux; Mirrors; Rotors; Stator cores; Stator windings; Turbines;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1964.4766049