DocumentCode :
1111520
Title :
Windings Temperature and Loss of Life of an Induction Machine Under Voltage Unbalance Combined With Over- or Undervoltages
Author :
Gnacinski, Piotr
Author_Institution :
Gdynia Maritime Univ., Gdynia
Volume :
23
Issue :
2
fYear :
2008
fDate :
6/1/2008 12:00:00 AM
Firstpage :
363
Lastpage :
371
Abstract :
This paper deals with the effect of simultaneous voltage unbalance and over- or undervoltage on windings temperature and thermal loss of life of an induction cage machine. The presented results of investigations are based on the experiment and thermal modeling. The influence of an angle of the complex voltage unbalance factor (CVUF) on machine heating is considered. The effect of synergy of voltage unbalance and voltage rms value deviation is presented. Two induction machines of different properties are compared. One of them has a comparatively weakly saturated magnetic circuit, and the other a comparatively strongly saturated circuit. The former is especially exposed to overheating in the conditions of undervoltage, and the latter in the conditions of overvoltage.
Keywords :
asynchronous machines; machine windings; overvoltage; complex voltage unbalance factor; induction cage machine; induction machine; machine heating; windings temperature; Complex voltage unbalance factor (CVUF); induction motor; temperature; voltage unbalance;
fLanguage :
English
Journal_Title :
Energy Conversion, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8969
Type :
jour
DOI :
10.1109/TEC.2008.918596
Filename :
4476161
Link To Document :
بازگشت