  • Abstract
    In this paper, unbalanced operations of induction and synchronous machines are discussed. The current-voltage differential equations, referred to the moving reference axes ¿ and ß, are derived directly from the general equations of armature reaction and induced voltage. Kron´s tensor transformation is used to develop a reciprocal system representing the actual machine under unbalanced operations. As an illustration, the line-to-line short-circuit case of a synchronous machine is solved in detail. An approximate solution for the differential equation with variable coefficients is proposed.
  • Keywords
    AC machines; Armature; Circuits; Coils; Differential equations; Machine windings; Space stations; Synchronous machines; Tensile stress; Voltage;