• DocumentCode
    1113128
  • Title

    Single-ensemble-based eigen-processing methods for color flow imaging - Part I. The Hankel-SVD filter

  • Author

    Yu, Alfred C H ; Cobbold, Richard S C

  • Author_Institution
    Hong Kong Univ., Hong Kong
  • Volume
    55
  • Issue
    3
  • fYear
    2008
  • fDate
    3/1/2008 12:00:00 AM
  • Firstpage
    559
  • Lastpage
    572
  • Abstract
    Because of their adaptability to the slow-time signal contents, eigen-based filters have shown potential in improving the flow detection performance of color flow images. This paper proposes a new eigen-based filter called the Hankel-SVD filter that is intended to process each slow- time ensemble individually. The new filter is derived using the notion of principal Hankel component analysis, and it achieves clutter suppression by retaining only the principal components whose order is greater than the clutter eigen- space dimension estimated from a frequency-based analysis algorithm. To assess its efficacy, the Hankel-SVD filter was first applied to synthetic slow-time data (ensemble size: 10) simulated from two different sets of flow parameters that model: (1) arterial imaging (blood velocity: 0 to 38.5 cm/s, tissue motion: up to 2 mm/s, transmit frequency: 5 MHz, pulse repetition period: 0.4 ms) and 2) deep vessel imaging (blood velocity: 0 to 19.2 cm/s, tissue motion: up to 2 cm/s, transmit frequency: 2 MHz, pulse repetition period: 2.0 ms). In the simulation analysis, the post-filter clutter- to-blood signal ratio (CBR) was computed as a function of blood velocity. Results show that for the same effective stopband size (50 Hz), the Hankel-SVD filter has a narrower transition region in the post-filter CBR curve than that of another type of adaptive filter called the clutter- downmixing filter. The practical efficacy of the proposed filter was tested by application to in vivo color flow data obtained from the human carotid arteries (transmit frequency: 4 MHz, pulse repetition period: 0.333 ms, ensemble size: 10). The resulting power images show that the Hankel-SVD filter can better distinguish between blood and moving- tissue regions (about 9 dB separation in power) than the clutter-downmixing filter and a fixed-rank multi-ensemble- based eigen-filter (which showed a 2 to 3 dB separation).
  • Keywords
    biomedical ultrasonics; blood vessels; eigenvalues and eigenfunctions; haemodynamics; image colour analysis; medical image processing; singular value decomposition; Hankel-SVD Filter; arterial imaging; blood velocity; color flow imaging; deep post-filter clutter- to-blood signal ratio; human carotid arteries; single ensemble-based eigenprocessing; singular value decomposition; tissue motion; Adaptive filters; Adaptive signal detection; Algorithm design and analysis; Analytical models; Blood; Computational modeling; Frequency estimation; In vivo; Signal analysis; Testing; Algorithms; Blood Flow Velocity; Coronary Circulation; Coronary Vessels; Echocardiography, Doppler, Color; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Phantoms, Imaging; Reproducibility of Results; Sensitivity and Specificity; Signal Processing, Computer-Assisted;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2008.682
  • Filename
    4476365