• DocumentCode
    1113207
  • Title

    Blind detection of nonlinearities in multiple-echo ultrasonic signals

  • Author

    Miralles, Ramón ; Vergara, Luis ; Salazar, Addisson ; Igual, Jorge

  • Author_Institution
    Univ. Politec. de Valencia, Valencia
  • Volume
    55
  • Issue
    3
  • fYear
    2008
  • fDate
    3/1/2008 12:00:00 AM
  • Firstpage
    637
  • Lastpage
    647
  • Abstract
    In this paper, we propose and analyze by means of simulations the use of surrogate data algorithms for blind detection of nonlinearities in multiple-echo ultrasonic signals. We assume a blind scheme so that no information about the input (emitted ultrasonic pulse) can be used. The metrics and equations that model some nonlinear situations are carefully reviewed. Also, closed form equations of the third-order metrics from a simplified second-order Volterra kernel are derived. Computer simulations show that the surrogate data technique is a potentially powerful tool for blind detection of nonlinearities in multiple-echo ultrasonic signals if adequate metrics are chosen. They also reveal interesting trade-offs among parameters that model ultrasonic systems and detection percentages.
  • Keywords
    Volterra equations; acoustic signal detection; ultrasonic propagation; blind detection; computer simulations; emitted ultrasonic pulse; multiple-echo ultrasonic signals; nonlinearities; second-order Volterra kernel; surrogate data algorithms; third-order metrics; ultrasonic propagation; Algorithm design and analysis; Analytical models; Biomedical imaging; Convolution; Ferroelectric materials; Kernel; Linearity; Nonlinear equations; Signal analysis; Signal processing;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2008.688
  • Filename
    4476371