DocumentCode :
1113418
Title :
Linear-geometry electric-field probe for DC corona measurements
Author :
Bouziane, A. ; Hartmann, G. ; Hidaka, K. ; Taplamacioglu, M.C. ; Waters, R.T.
Author_Institution :
Univ. of Wales Coll. of Cardiff, UK
Volume :
141
Issue :
2
fYear :
1994
fDate :
3/1/1994 12:00:00 AM
Firstpage :
111
Lastpage :
117
Abstract :
The technique for DC corona field measurement by means of a biased-current probe has been adapted to a linear geometry for use in corona discharges. Calibration of the probe requires account to be taken of the finite length of the collector. Design parameters are given, and calibration is obtained by means of analytical computation which simulates the biased probe by a system of inclined planes, and by a three dimensional charge simulation computer program
Keywords :
calibration; corona; digital simulation; electric field measurement; physics computing; plasma probes; DC corona measurements; analytical computation; biased-current probe; calibration; corona discharges; inclined planes; linear-geometry electric-field probe; three dimensional charge simulation computer;
fLanguage :
English
Journal_Title :
Science, Measurement and Technology, IEE Proceedings -
Publisher :
iet
ISSN :
1350-2344
Type :
jour
DOI :
10.1049/ip-smt:19941012