Abstract :
Leak detection in the coolant loops of Fast Breeder Reactor (FBR) is critical for the safety of the reactors. This paper discusses the feasibility of using Raman Distributed Temperature Sensor (RDTS) for leak detection in double walled pipelines of primary sodium circuits in FBR. The leak detection is based on the resultant change in temperature due to leak. Since handling sodium is difficult, as a “proof of concept”, leak detection is demonstrated on a test loop with water as the leaking medium. Path delay multiplexing is adopted to improve the spatial resolution from 1.02 m to 0.51 m.
Keywords :
fibre optic sensors; fission reactor coolants; fission reactor monitoring; leak detection; liquid metal fast breeder reactors; FBR; RDTS; Raman distributed temperature sensor; coolant loops; double walled pipelines; fast breeder reactor; fiber optic sensors; leak detection; leaking medium; path delay multiplexing; primary sodium circuits; Leak detection; Monitoring; Optical sensors; Pipelines; Spatial resolution; Temperature measurement; Temperature sensors; Fiber sensor; Raman distributed sensing; leak detection; reactor; temperature monitoring;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2014.2328355
Filename :
6866250
Link To Document :
بازگشت