• DocumentCode
    1115953
  • Title

    Influence of converters on the superconducting field-circuit of a three-phase synchronous generator

  • Author

    Gröter, H.P. ; Lorenzen, H. ; Rehm, W. ; Schweiger, R.

  • Author_Institution
    Inst. of Electr. Machines, Tech. Univ. of Munchen, Germany
  • Volume
    27
  • Issue
    2
  • fYear
    1991
  • fDate
    3/1/1991 12:00:00 AM
  • Firstpage
    2480
  • Lastpage
    2483
  • Abstract
    Experimental investigations of the influence of converter feeding the field circuit of a three-phase synchronous generator with a superconducting field winding have been performed. Four converter circuits have been tested: a B6 three-phase bridge, two parallel B6 three-phase bridges, a three-phase bridge with bypass thyristors, and a high-current power-MOSFET converter. Steady-state and transient operation have been tested. There was a special interest in the harmonics generated by the converter circuits and their power dissipation in the low-temperature region. The thermal reaction of the field circuit has also been considered. A method has been developed to prevent the superconducting winding from the quenching in transient operation
  • Keywords
    bridge circuits; machine windings; power convertors; superconducting machines; synchronous generators; thyristor applications; bypass thyristors; converter circuits; harmonics; high-current power-MOSFET converter; low-temperature region; power dissipation; quenching; superconducting field winding; superconducting field-circuit; thermal reaction; three-phase bridge; three-phase synchronous generator; transient operation; Bridge circuits; Circuit testing; Delay estimation; Frequency; Power dissipation; Power system harmonics; Steady-state; Synchronous generators; Temperature; Voltage;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.133721
  • Filename
    133721