DocumentCode
1118319
Title
Performance of interior-type permanent-magnet alternator
Author
Chalmers, B.J.
Author_Institution
Dept. of Electr. Eng. & Electron., Univ. of Manchester Inst. of Sci. & Technol., UK
Volume
141
Issue
4
fYear
1994
fDate
7/1/1994 12:00:00 AM
Firstpage
186
Lastpage
190
Abstract
Theoretical analysis of an isolated, interior-type permanent magnet alternator feeding a resistive load shows how inverse saliency causes output voltage to rise as load is increased. Computations and practical tests illustrate the influence of machine parameters, including quadrature-axis saturation, upon performance
Keywords
alternators; load (electric); machine testing; machine theory; permanent magnet machines; interior-type permanent magnet alternator; isolat; load; machine parameters; output voltage; performance; quadrature-axis saturation; resistive load;
fLanguage
English
Journal_Title
Electric Power Applications, IEE Proceedings -
Publisher
iet
ISSN
1350-2352
Type
jour
DOI
10.1049/ip-epa:19941207
Filename
296489
Link To Document