DocumentCode :
1119075
Title :
Motor Fault Detection Using a Rogowski Sensor Without an Integrator
Author :
Poncelas, Oscar ; Rosero, Javier A. ; Cusidó, Jordi ; Ortega, Juan Antonio ; Romeral, Luis
Author_Institution :
Dept. of Electron. Eng., Univ. Politec. de Catalunya, Terrassa, Spain
Volume :
56
Issue :
10
fYear :
2009
Firstpage :
4062
Lastpage :
4070
Abstract :
This paper presents a new approach for the current acquisition system in motor fault detection applications. This paper includes the study, design, and implementation of a Rogowski-coil current sensor without the integrator circuit that is typically used. The circuit includes an autotuning block able to adjust to different motor speeds. Equalizing the amplitudes of the fundamental and fault harmonics leads to higher precision current measurements. The resulting compact sensor is used as a current probe for fault detection in induction motors through motor current signal analysis. The use of a Rogowski coil without an integrator allows a better discrimination of the fault harmonics around the third and fifth main harmonics. Finally, the adaptive conditioning circuit is tested over an induction machine drive. Results are presented, and quantitative comparisons are carried out.
Keywords :
fault diagnosis; induction motor drives; signal processing; Rogowski sensor; adaptive conditioning circuit; current acquisition system; current sensor; fault harmonics; induction machine drives; motor current signal analysis; motor fault detection; Current sensor; Rogowski; motor current signal analysis (MCSA); motor drive;
fLanguage :
English
Journal_Title :
Industrial Electronics, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0046
Type :
jour
DOI :
10.1109/TIE.2009.2025715
Filename :
5130237
Link To Document :
بازگشت