Abstract
This brief presents the experimental transient thermal profiles of the cathode surface of a practical potted heater cathode structure (standard 250 Spectra-Mat heater-cathode packaging). Temperature-time history has been obtained experimentally for various input heater power levels. The experimental results have been compared with the theoretical predictions earlier reported, and it has been found that in all the cases, the theoretical predictions are within 10% of the experimental results, thus validating the earlier reported theory
Keywords
thermionic cathodes; transient response; 250 Spectra-Mat heater-cathode packaging; cathode surface; potted heater-cathode; temperature-time history; transient thermal response; Cathodes; Gain measurement; History; Impedance measurement; Packaging; Software packages; Steady-state; Temperature measurement; Voltage; Wires;