Abstract
An instrument has been constructed which simultaneously measures optical path length at two wavelengths and so permits determination of average refractive index over the common path and hence distance to
or better without extensive meteorological observations. Using a He-Ne laser (6328 Å) and a filtered high-pressure mercury arc lamp (3681 Å), the instrument is expected to measure distances to 15 kilometers with accuracies as high as a few parts in ten million. Preliminary measurements over a 5.3-km path give a standard deviation of 0.15 cm, or better than
.
or better without extensive meteorological observations. Using a He-Ne laser (6328 Å) and a filtered high-pressure mercury arc lamp (3681 Å), the instrument is expected to measure distances to 15 kilometers with accuracies as high as a few parts in ten million. Preliminary measurements over a 5.3-km path give a standard deviation of 0.15 cm, or better than
.Keywords
Density measurement; Instruments; Length measurement; Measurement standards; Meteorology; Optical filters; Optical refraction; Optical variables control; Refractive index; Wavelength measurement;