Abstract :
A wavelength-tunable acousto-optical Ti:LiNbO3 TE-TM converter, followed by a 45° linear polariser, can be used to measure the four Stokes parameters. A demonstration unit for 1.5 μm wavelength operation with 9 MHz electrical measurement bandwidth, roughly 0.04 rad accuracy and 250 GHz optical bandwidth has been developed
Keywords :
acousto-optical devices; integrated optics; light polarisation; lithium compounds; optical polarisers; titanium; 1.5 micron; 250 GHz; 45° linear polariser; 9 MHz; LiNbO3:Ti; Stokes parameters measurement; acousto-optical TE-TM converter; electrical measurement bandwidth; optical bandwidth; wavelength-selective polarisation analyser; wavelength-tunable acoustooptical convertor;