DocumentCode :
1126001
Title :
First User Results From the HOTWAXS Detector System
Author :
Bateman, J.E. ; Derbyshire, G.E. ; Diakun, G. ; Duxbury, D.M. ; Fairclough, J.P.A. ; Harvey, I. ; Helsby, W.I. ; Mai, S.-M. ; Mykhaylyk, O.O. ; Sankar, G. ; Spill, E.J. ; Stephenson, R.
Author_Institution :
Technol. Div., Rutherford Appleton Lab., Didcot
Volume :
55
Issue :
2
fYear :
2008
fDate :
4/1/2008 12:00:00 AM
Firstpage :
729
Lastpage :
733
Abstract :
Over the past 10 years combined techniques such as small angle and wide angle X-ray scattering (SAXS/WAXS) and X-ray absorption spectroscopy (XAS) with X-ray diffraction (XRD), have become the mainstay of time resolved experimental studies carried out at synchrotron radiation sources (SRS). However, these techniques have been limited by the detectors used to measure the wide angle scattering/diffraction pattern, and therefore restrict the dynamic experiments that can be studied. The HOTWAXS (High Overall Throughput Wide-Angle X-ray Scattering) detector project was designed to address this issue by producing a position sensitive, parallax free, high count rate, photon counting detector based on microstrip gas chamber (MSGC) technology. The initial experiments, performed on station 16.1 of the Daresbury SRS, with a high density polyethylene sample, confirmed the local count rate per channel to be 1 times 106 counts per second. A global count rate over the 512 channel detector of 27 times 106 counts per second was also measured for this sample. Time resolved experiments on stations 2.1 and 9.3 with real ´user´ samples have also been performed, the results of which are presented.
Keywords :
X-ray absorption spectra; X-ray diffraction; X-ray scattering; photon counting; polymers; position sensitive particle detectors; synchrotron radiation; HOTWAXS detector system; High Overall Throughput Wide-Angle X-ray Scattering; MSGC; SAXS; WAXS; X-ray absorption spectroscopy; X-ray diffraction; XAS; XRD; count rate; microstrip gas chamber technology; parallax free detector; photon counting detector; polyethylene; position sensitive detector; small angle X-ray scattering; synchrotron radiation sources; time resolved experiment; wide angle X-ray scattering; Electromagnetic scattering; Electromagnetic wave absorption; Goniometers; Position sensitive particle detectors; Spectroscopy; Synchrotron radiation; X-ray detection; X-ray detectors; X-ray diffraction; X-ray scattering; Gas detector; MSGC; WAXS; position sensitive; synchrotron radiation;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2008.918525
Filename :
4484229
Link To Document :
بازگشت