• DocumentCode
    112665
  • Title

    Design of a Calibrated Liquid Level Sensor Transducer for Detecting Rainfall of Botanic Garden

  • Author

    Cheng-Ta Chiang ; Ping-Chen Tsai

  • Author_Institution
    Dept. of Electr. Eng., Nat. Chiayi Univ., Chiayi, Taiwan
  • Volume
    15
  • Issue
    6
  • fYear
    2015
  • fDate
    Jun-15
  • Firstpage
    3311
  • Lastpage
    3316
  • Abstract
    In this paper, a calibrated liquid level sensor transducer for detecting rainfall of botanic garden is newly proposed. The output signal is a pulse stream, it could be easily sent over a wide range of transmission media, such as package switch network, radio, optical, infrared, ultrasonic, and so on. Another innovation is that a calibration method is proposed to easily adjust parameters to calibrate various liquid level sensors. By collocating with a liquid level sensor that has a range of 3.97 to 123.34 mm, the corresponding output frequency ranges from 3.12 to 57.25 kHz. After calibration, the measured maximum frequency error is 1.46%. Measurement results have successfully verified all the functions and performance of the proposed calibrated liquid level sensor transducer and confirmed it to be applied on detecting rainfall of botanic garden. The proposed calibrated liquid level sensor transducer is suitable for devices of detecting liquid level.
  • Keywords
    calibration; flow sensors; level measurement; rain; transducers; botanic garden rainfall detection; calibrated liquid level sensor transducer; frequency 3.12 kHz to 57.25 kHz; pulse stream; transmission media; Calibration; Frequency measurement; Liquids; Magnetic liquids; Semiconductor device measurement; Sensors; Transducers; Rainfall; liquid level sensor; liquid level sensor transducer;
  • fLanguage
    English
  • Journal_Title
    Sensors Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1530-437X
  • Type

    jour

  • DOI
    10.1109/JSEN.2014.2388216
  • Filename
    7001067