DocumentCode :
112681
Title :
Wireless Gigabit Data Telemetry for Large-Scale Neural Recording
Author :
Yen-Cheng Kuan ; Yi-Kai Lo ; Yanghyo Kim ; Chang, Mau-Chung Frank ; Wentai Liu
Author_Institution :
Dept. of Electr. Eng., Univ. of California, Los Angeles, Los Angeles, CA, USA
Volume :
19
Issue :
3
fYear :
2015
fDate :
May-15
Firstpage :
949
Lastpage :
957
Abstract :
Implantable wireless neural recording from a large ensemble of simultaneously acting neurons is a critical component to thoroughly investigate neural interactions and brain dynamics from freely moving animals. Recent researches have shown the feasibility of simultaneously recording from hundreds of neurons and suggested that the ability of recording a larger number of neurons results in better signal quality. This massive recording inevitably demands a large amount of data transfer. For example, recording 2000 neurons while keeping the signal fidelity (> 12 bit,> 40 KS/s per neuron) needs approximately a 1-Gb/s data link. Designing a wireless data telemetry system to support such (or higher) data rate while aiming to lower the power consumption of an implantable device imposes a grand challenge on neuroscience community. In this paper, we present a wireless gigabit data telemetry for future large-scale neural recording interface. This telemetry comprises of a pair of low-power gigabit transmitter and receiver operating at 60 GHz, and establishes a short-distance wireless link to transfer the massive amount of neural signals outward from the implanted device. The transmission distance of the received neural signal can be further extended by an externally rendezvous wireless transceiver, which is less power/heat-constraint since it is not at the immediate proximity of the cortex and its radiated signal is not seriously attenuated by the lossy tissue. The gigabit data link has been demonstrated to achieve a high data rate of 6 Gb/s with a bit-error-rate of 10-12 at a transmission distance of 6 mm, an applicable separation between transmitter and receiver. This high data rate is able to support thousands of recording channels while ensuring a low energy cost per bit of 2.08 pJ/b.
Keywords :
bioelectric phenomena; biological tissues; biomedical telemetry; brain; brain-computer interfaces; medical signal processing; neurophysiology; transceivers; bit error rate; brain dynamics; data transfer; externally rendezvous wireless transceiver; freely moving animals; gigabit data link; implantable device; implantable wireless neural recording; large-scale neural recording; lossy tissue; low-power gigabit transmitter; neural interactions; neuroscience; receiver; short-distance wireless link; simultaneously acting neurons; wireless gigabit data telemetry; Implants; Neurons; Receivers; Skin; Telemetry; Transmitters; Wireless communication; Brain???machine interface; brain-machine interface; data telemetry; implant; large-scale; neural interface; prosthetics; transceiver; wireless neural recording;
fLanguage :
English
Journal_Title :
Biomedical and Health Informatics, IEEE Journal of
Publisher :
ieee
ISSN :
2168-2194
Type :
jour
DOI :
10.1109/JBHI.2015.2416202
Filename :
7066952
Link To Document :
بازگشت