  • Abstract
    A tangential far infrared interferometer/polarimeter system has been upgraded for the measurement of two-dimensional electron density and toroidal magnetic field profiles on the National Spherical Torus Experiment (NSTX). The system employs a three-wavelength configuration that simultaneously produces interferometric phase shift and Faraday rotation polarimetric data from a single detector for each channel. Three CH3OH lasers (λ=119 μm) including Stark-tuned laser cavities are optically pumped by a CO2 laser tuned to 9.7 μm. For high time-resolution measurements, the modulation frequency in the heterodyne interferometer is operated at ∼ 7 MHz via the Stark-tuned laser, serving as the local oscillator in this system. Unwanted phase changes introduced by mechanical vibrations originating from various sources were eliminated by extensive work including a specially designed vibration-free stand for the retroreflector. The system is designed to have a full remote control capacity using the LABVIEW program via fiber links and real time signal processing circuits with a tracking receiver technique. A high IF frequency and a low noise fringe counting system enabled the system to measure wide-band density fluctuations such as microturbulence and magnetohydrodynamics. In this paper, a comparison study of the measured electron density with Thomson scattering data and para/diamagnetism effects measured via polarimetry signal and compared with the calculated value using the EFIT equilibrium code are presented. A recent upgrade plan together with the technical details of the system development will also be described.
  • Keywords
    Tokamak devices; heterodyne detection; laser cavity resonators; measurement by laser beam; plasma density; plasma diagnostics; plasma fluctuations; plasma magnetohydrodynamics; plasma toroidal confinement; plasma turbulence; signal processing equipment; submillimetre wave lasers; vibration isolation; 119 mum; 9.7 mum; CH3OH lasers; CO2 laser; Faraday rotation polarimetric data; LABVIEW program; Stark-tuned laser cavities; Thomson scattering; diamagnetism effects; equilibrium fitting code; far infrared laser tangential interferometry; far infrared laser tangential polarimetry; full remote control capacity; heterodyne interferometer; interferometric phase shift; low noise fringe counting system; magnetohydrodynamics; mechanical vibrations; microturbulence; modulation frequency; national spherical torus experiment; paramagnetism effects; real time signal processing circuits; retroreflector; toroidal magnetic field profiles; tracking receiver technique; two-dimensional electron density; wide-band density fluctuations; Density measurement; Electrons; Finite impulse response filter; Frequency measurement; Laser tuning; Optical interferometry; Optical scattering; Phase shifting interferometry; Polarimetry; Pump lasers; Density fluctuation measurement; Stark-tuned laser; far infrared laser; interferometer; polarimeter;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/TPS.2004.833386
  • Filename
    1341545