DocumentCode
1130530
Title
Low cost video scaler and gray scale integrator
Author
Pietras, Bradley W. ; Bolanowski, Stanley J.
Author_Institution
Inst. for Sensory Res., Syracuse Univ., NY, USA
Volume
41
Issue
7
fYear
1994
fDate
7/1/1994 12:00:00 AM
Firstpage
698
Lastpage
703
Abstract
A hybrid digital/analog device capable of making high-resolution linear and area measurements from a standard monochromatic video image is described. The device is capable of dynamic as well as static data acquisition when used in conjunction with standard NTSC video recording equipment. Digital output allows for computer interfacing. Linear dimensions are obtained by electronically superimposing two horizontal and two vertical scaling lines on a video monitor. Each linear dimension has an eight-bit resolution and is displayed on the front panel with seven segment LEDs. Eight-bit, digital-to-analog converters are also used to provide analog outputs. A measurement of the temporal deformation pattern of the accessory capsule surrounding a mechanoreceptor (Pacinian corpuscles) in response to vibratory displacements is demonstrated. Area measurements are obtained via a window comparator, a 6 MHz clock, and a 16-bit digital-to-analog converter. Data is only valid within the zone set by the scaling lines, allowing data regions to be isolated from noise, etc. The 16-bit digital signal measuring the area of interest is then converted for analog output. The measurement of the consensual pupillary reflex in response to full-field illumination (Ganzfeld) is given as an example.
Keywords
area measurement; biological techniques and instruments; biomedical equipment; spatial variables measurement; television applications; 6 MHz; LEDs; Pacinian corpuscles; computer interfacing; consensual pupillary reflex; digital output; digital-to-analog converters; dynamic data acquisition; full-field illumination; gray scale integrator; high-resolution area measurements; high-resolution linear measurements; hybrid digital/analog device; low cost video scaler; mechanoreceptor accessory capsule; scaling lines superimposition; standard NTSC video recording equipment; standard monochromatic video image; static data acquisition; temporal deformation pattern; vibratory displacements; Area measurement; Computer interfaces; Computerized monitoring; Costs; Data acquisition; Digital-analog conversion; Displacement measurement; Light emitting diodes; Measurement standards; Video recording; Animals; Calibration; Equipment Design; Humans; Image Processing, Computer-Assisted; Microscopy, Video; Pacinian Corpuscles; Reflex, Pupillary; Video Recording;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/10.301738
Filename
301738