DocumentCode :
1132788
Title :
Optical Calibration of Geostationary Satellite Tracking Systems
Author :
Kawase, S. ; Kawaguchi, N. ; Tanaka, T. ; Tomita, K.
Author_Institution :
Kashima Branch, Radio Research Laboratories, Japan
Issue :
2
fYear :
1981
fDate :
3/1/1981 12:00:00 AM
Firstpage :
167
Lastpage :
172
Abstract :
A precise calibration method for range and angle observation has been developed for eliminating the systematic error of tracking systems, thus improving the accuracy of orbit determination for geostationary satellites. The principle of calibration is based on an orbit determination employing a point of optical angle observation in addition to radio tracking observation, in which we estimate observation bias parameters simultaneously with orbital elements, including the effects of geodetic mismodelings. As shown by an actual calibration experiment in our ground station, orbit determinations is sufficiently accurate that the error of predicting satellite range falls within a few meters at four days after the day of orbit determination.
Keywords :
Calibration; Collimators; Frequency conversion; Laboratories; Observability; Observatories; Optical interferometry; Parameter estimation; Satellite broadcasting; Satellite ground stations;
fLanguage :
English
Journal_Title :
Aerospace and Electronic Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9251
Type :
jour
DOI :
10.1109/TAES.1981.309142
Filename :
4102466
Link To Document :
بازگشت