Author :
Wanderer, P. ; Anerella, M. ; Ganetis, G. ; Garber, M. ; Ghosh, A.K. ; Greene, A. ; Gupta, R. ; Jain, A. ; Kahn, S. ; Kelly, E. ; Morgan, G. ; Muratore, J. ; Prodell, A. ; Rehak, M. ; Rohrer, E.P. ; Sampson, W. ; Shutt, R. ; Thomas, R. ; Thompson, P. ; Wi
Author_Institution :
RHIC Project, Brookhaven Nat. Lab., Upton, NY, USA
Abstract :
Over a period of ten months, a 15 m-long, 50 mm-aperture superconducting SSC Collider dipole was taken through a series of thermal and power cycles to check for changes in performance. One quench below operating current was experienced during this period. Small changes in the coil preload and certain harmonics were observed
Keywords :
beam handling equipment; proton accelerators; superconducting magnets; synchrotrons; testing; 15 m; 50 mm; SSC Collider dipole; coil preload; harmonics; partial lifetime test; power cycles; quench; superconducting dipole; thermal cycles; Apertures; Laboratories; Life estimation; Lifetime estimation; Magnetic separation; Research and development; Superconducting coils; Superconducting magnets; Temperature; Testing;