• DocumentCode
    1134066
  • Title

    Design, construction and operation of the Fast Protection System of the windings of RFX

  • Author

    Bellina, Fabrizio ; Chitarin, Giuseppe ; Guamieri, M. ; Trevisan, Francesco

  • Author_Institution
    Dept. of Electr. Eng., Padova Univ., Italy
  • Volume
    30
  • Issue
    4
  • fYear
    1994
  • fDate
    7/1/1994 12:00:00 AM
  • Firstpage
    1851
  • Lastpage
    1854
  • Abstract
    The protection of the windings of RFX against fast electric faults relies on an original dedicated Fast Protection System able to operate within 1 ms. The first ring of the protection chain is the fault protection system of the winding, named RGM, that consists of: about hundred highly reliable voltage and current probes, all electric signal lines and an analog-digital device where signals are processed and logic alarms are generated. RGM is an original machine that required a careful design and manufacturing work. After a long test and adjustment phase it now operates properly. It has already operated against some earth faults which, due to low level of earth current, mere not dangerous for the machine but very hard to detect
  • Keywords
    machine windings; overvoltage protection; power system protection; superconducting magnets; RFX windings; all electric signal lines; analog-digital device; current probes; earth faults; fast electric faults; fast protection system; logic alarms; voltage probes; Analog-digital conversion; Earth; Logic devices; Manufacturing; Probes; Protection; Signal generators; Signal processing; Testing; Voltage;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.305621
  • Filename
    305621