Abstract :
A simple model is presented that can describe the electro-mechanical state of a multifilamentary wire. An elastic cylinder model is used to derive the strain state analytically. Axial and transverse forces came a position dependent critical current density in the wire. The integral critical current of such a wire is calculated. The effect of two different parameters, the hydrostatic and the deviatoric strain, on the critical current is compared. The critical current reduction of a model wire due to various external loads in a Nb 3Sn wire is analysed. Finally the position of the superconducting filaments is considered
Keywords :
critical current density (superconductivity); elastic deformation; niobium compounds; superconducting materials; Nb3Sn; axial forces; brittle wound multifilamentary wire; critical current reduction; deviatoric strain; elastic cylinder model; electro-mechanical state; external forces; external loads; hydrostatic strain; integral critical current; position dependent critical current density; strain state; superconducting filaments; transverse forces; Capacitive sensors; Conductors; Critical current; Critical current density; Integrated circuit modeling; Magnetic field induced strain; Superconducting filaments and wires; Superconducting magnets; Superconductivity; Wounds;
Journal_Title :