DocumentCode
1134204
Title
Partial Discharge Testing under Direct Voltage Conditions
Author
Bever, Renate S. ; Westrom, John L.
Author_Institution
University of the District of Columbia
Issue
1
fYear
1982
Firstpage
82
Lastpage
93
Abstract
DC partial discharge (PD) (corona) testing is performed using a multichannel analyzer for pulse storing, and data is collected during increase of voltage and at quiescent voltage levels. Thus high voltage ceramic disk capacitors were evaluated by obtaining PD data interspersed during an accelarated life test. Increased PD activity was found early in samples that later failed catastrophically. By this technique, trends of insulation behavior are revealed sensitively and nondestructively in high voltage dc components.
Keywords
Breakdown voltage; Conducting materials; Corona; Dielectrics; Internal stresses; NASA; Partial discharges; Residual stresses; Surface discharges; Testing;