• DocumentCode
    1134672
  • Title

    Quench and protection characteristics of the GEM test coil

  • Author

    Chaniotakis, Emanuel A. ; Marston, Peter G.

  • Author_Institution
    Plasma Fusion Center, MIT, Cambridge, MA, USA
  • Volume
    30
  • Issue
    4
  • fYear
    1994
  • fDate
    7/1/1994 12:00:00 AM
  • Firstpage
    2070
  • Lastpage
    2073
  • Abstract
    The GEM test coil, will be wound from 70 m of conductor identical to that used in the full scale magnet. The coil configuration will duplicate the field distribution of the full scale magnet and current control will duplicate full scale current decay characteristics. Therefore, quench/protection analysis of this coil will reveal very important information about the behavior of the full scale model. Due to the uncertainty associated with the contest between the cable, the conduit and the sheath, a parametric analysis has been performed in order to determine and bracket the behavior. With no electrical contact the quench evolves normally until, due to heat transfer from the sheath into the cable, the superconductor temperature becomes critical and the entire length becomes normal
  • Keywords
    position sensitive particle detectors; superconducting magnets; superconducting transition temperature; GEM detector; GEM test coil; NbTi; critical temperature; heat transfer; protection; quench; superconductor temperature; Cable shielding; Coils; Conductors; Magnetic analysis; Power cables; Protection; Superconducting cables; Superconducting magnets; Testing; Wounds;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.305676
  • Filename
    305676