• DocumentCode
    1134844
  • Title

    The injection septum magnets of the SPring-8 storage ring

  • Author

    Kumagai, Keiko ; Matsui, Sakuo

  • Author_Institution
    RIKEN, JAERI, Hyogo, Japan
  • Volume
    30
  • Issue
    4
  • fYear
    1994
  • fDate
    7/1/1994 12:00:00 AM
  • Firstpage
    2134
  • Lastpage
    2137
  • Abstract
    Three DC septum magnets and a pulsed septum magnet are used for the injection of the SRing-8 storage ring. This paper describes the design principle of these injection septum magnets and the electromagnetic performances of a prototype pulsed magnet. The peak strength of the magnetic stray field of the pulsed septum magnet is 1.3 gauss on the bump orbit, and is lower than the limit of sensitivity of the measurement on the reference orbit when the field strength in the magnet gap is 5600 gauss and the pulse width is 65 μsec
  • Keywords
    beam handling equipment; beam handling techniques; electron accelerators; magnetic fields; storage rings; 1.3 G; DC septum magnets; SPring-8; design; injection septum magnets; magnetic stray field; EMP radiation effects; Electromagnetic measurements; Extraterrestrial measurements; Gaussian processes; Magnetic field measurement; Magnets; Prototypes; Pulse measurements; Space vector pulse width modulation; Storage rings;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.305692
  • Filename
    305692