DocumentCode
1135740
Title
Flyback-forward power factor correction circuit with line-frequency ripple suppression
Author
Liang, T.J. ; Ai, T.-H. ; Chen, J.F.
Author_Institution
Dept. of Electr. Eng., Nat. Cheng Kung Univ., Tainan, Taiwan
Volume
149
Issue
6
fYear
2002
fDate
11/1/2002 12:00:00 AM
Firstpage
474
Lastpage
480
Abstract
A flyback-forward converter with power factor correction and line ripple suppression is proposed. The topology combines forward and flyback circuits with a post regulator. To maintain a high power factor, the flyback circuit delivers the major output power, while the output voltage is controlled by the post regulator with fast response to suppress line-frequency ripple without the use of a high voltage bulk capacitor or current sensor on the primary side. The circuit features high power factor and low output line-frequency ripple in discontinuous conduction mode. A theoretical analysis and experimental results are presented.
Keywords
AC-DC power convertors; power control; power factor correction; voltage control; 100 kHz; 110 V; 15 V; 18 V; 2 A; 60 Hz; AC/DC converters; current sensor; discontinuous conduction mode; fast response; flyback circuit delivers; flyback circuits; flyback-forward power factor correction circuit; forward circuits; high power factor; high voltage bulk capacitor; line-frequency ripple suppression; major output power control; output voltage control; post regulator; total harmonic distortion;
fLanguage
English
Journal_Title
Electric Power Applications, IEE Proceedings -
Publisher
iet
ISSN
1350-2352
Type
jour
DOI
10.1049/ip-epa:20020524
Filename
1176561
Link To Document