Title :
A Comparison of Noncoherent and Coherent MTI Improvement Factors
Author :
Kretschmer, Frank F., Jr. ; Lin, Feng-Ling C. ; Lewis, Bernard L.
Author_Institution :
Naval Research Laboratory
fDate :
5/1/1983 12:00:00 AM
Abstract :
An analysis based on statistical considerations and Monte Carlo simulations indicates that a noncoherent moving target indicator (MTI) using a linear envelope detector differs from one using a square law envelope detector. The square law envelope detector is usually described in the literature because of ease of analysis, and it is commonly stated or implied that the results are the same for the two cases because of the similar spectral characteristics of the detectors. A comparison is made between the two noncoherent MTIs and the coherent MTI in terms of clutter attenuation and MTI improvement factors.
Keywords :
Attenuation; Envelope detectors; Filters; Laboratories; Performance analysis;
Journal_Title :
Aerospace and Electronic Systems, IEEE Transactions on
DOI :
10.1109/TAES.1983.309320