• DocumentCode
    1138269
  • Title

    Actively generated noise liquid flowmeter

  • Author

    TANISAWA, Shigeru ; Hirose, Haruo ; Yoshihisa, Nobuyuki

  • Author_Institution
    Nippon Inst. of Technol., Saitama, Japan
  • Volume
    41
  • Issue
    5
  • fYear
    1994
  • Firstpage
    778
  • Lastpage
    784
  • Abstract
    A new noise flowmeter with two transducers has been tested experimentally in water. It detects the noises generated by the interaction between artificially introduced air bubbles and a built-in obstacle with a downstream transducer, and differentiates them from the external noises detected by the upstream transducer in a pipe. The system includes processing instrumentation with functions such as averaging and difference-operating for reduction of external noise effects.<>
  • Keywords
    acoustic noise; bubbles; flow measurement; flowmeters; underwater sound; actively generated noise liquid flowmeter; artificially introduced air bubbles; built-in obstacle; difference-operating; downstream transducer; external noises; external noises detection; noise flowmeter; processing instrumentation; transducers; upstream transducer; water; Acoustic noise; Acoustic transducers; Fluid flow measurement; Instruments; Noise generators; Noise level; Noise reduction; Noise shaping; Stability; Testing;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/58.308514
  • Filename
    308514