DocumentCode :
1139316
Title :
Nonlinear sinogram smoothing for low-dose X-ray CT
Author :
Li, Tianfang ; Li, Xiang ; Wang, Jing ; Wen, Junhai ; Lu, Hongbing ; Hsieh, Jiang ; Liang, Zhengrong
Author_Institution :
Depts. of Phys. & Astron. & Radiol., State Univ. of New York, Stony Brook, NY, USA
Volume :
51
Issue :
5
fYear :
2004
Firstpage :
2505
Lastpage :
2513
Abstract :
When excessive quantum noise is present in extremely low dose X-ray CT imaging, statistical properties of the data has to be considered to achieve a satisfactory image reconstruction. Statistical iterative reconstruction with accurate modeling of the noise, rather than a filtered back-projection (FBP) with low-pass filtering, is one way to deal with the problem. Estimating a noise-free sinogram to satisfy the FBP reconstruction for the Radon transform is another way. The benefits of the latter include a higher computation efficiency, more uniform spatial resolution in the reconstructed image, and less modification of the current machine configurations. In a clinic X-ray CT system, the acquired raw data must be calibrated, in addition to the logarithmic transform, to achieve the high diagnostic image quality. The calibrated projection data or sinogram no longer follow a compound Poisson distribution in general, but are close to a Gaussian distribution with signal-dependent variance. In this paper, we first investigated a relatively accurate statistical model for the sinogram data, based on several phantom experiments. Then we developed a penalized likelihood method to smooth the sinogram, which led to a set of nonlinear equations that can be solved by iterated conditional mode (ICM) algorithm within a reasonable computing time. The method was applied to several experimental datasets acquired at 120 kVp, 10 mA/20 mA/50 mA protocols with a GE HiSpeed multi-slice detector CT scanner and demonstrated a significant noise suppression without noticeable sacrifice of the spatial resolution.
Keywords :
Gaussian distribution; Radon transforms; computerised tomography; dosimetry; image reconstruction; iterative methods; low-pass filters; nonlinear equations; phantoms; quantum noise; GE HiSpeed multislice detector CT scanner; Gaussian distribution; Radon transform; calibrated projection data; clinic X-ray CT system; compound Poisson distribution; computation efficiency; computing time; current machine configurations; filtered back-projection; high diagnostic image quality; image reconstruction; iterated conditional mode algorithm; logarithmic transform; low dose X-ray CT imaging; low-pass filtering; noise suppression; noise-free sinogram; nonlinear equations; nonlinear sinogram smoothing; penalized likelihood method; penalized weighted least square; phantom experiments; protocols; quantum noise; reconstructed image; relatively accurate statistical model; signal-dependent variance; spatial resolution; statistical iterative reconstruction; statistical properties; Computed tomography; Filtering; Gaussian distribution; Image quality; Image reconstruction; Low pass filters; Optical imaging; Smoothing methods; Spatial resolution; X-ray imaging; CT; Iterated conditional mode; X-ray computed tomography; low dose; penalized weighted least square; sinogram smoothing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2004.834824