DocumentCode :
1139394
Title :
Stator Windings Fault Diagnostics of Induction Machines Operated From Inverters and Soft-Starters Using High-Frequency Negative-Sequence Currents
Author :
Briz, Fernando ; Degner, Michael W. ; Guerrero, Juan M. ; García, Pablo
Author_Institution :
Dept. of Electr., Comput., & Syst. Eng., Univ. of Oviedo, Gijon, Spain
Volume :
45
Issue :
5
fYear :
2009
Firstpage :
1637
Lastpage :
1646
Abstract :
This paper studies the application of high-frequency voltage excitation-based stator winding diagnostic methods to three-phase ac machines operated from power converters that create the necessary high-frequency excitation as part of their normal operation. This paper focuses on two specific operating modes: 1) machines operated from inverters in the overmodulation region and 2) machines operated from soft-starters during startup. In both cases, high-frequency (in the range of the hundred hertz) voltage components at well-defined frequencies are created. The negative-sequence currents induced from these high-frequency voltages are shown to contain accurate information on the level of asymmetry (fault) in the machine. This information is significantly richer than exists in other modes of operation, i.e., inverters working in the linear modulation region or soft-starters in the steady state, and provides interesting opportunities to complement other diagnostic methods.
Keywords :
asynchronous machines; invertors; stators; fault diagnostics; high-frequency negative-sequence currents; induction machines; inverters; overmodulation region; soft-starters; startup; stator windings; voltage components; Fault diagnosis; high-frequency signal injection; induction motor drives; overmodulation; soft-starters; stator winding fault detection;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/TIA.2009.2027198
Filename :
5166462
Link To Document :
بازگشت