DocumentCode :
1139659
Title :
Dynamic cardiac SPECT with Tc-99m teboroxime: compensation for rapid myocardial washout and high liver uptake
Author :
Chen, Ji ; Galt, James R. ; Aarsvold, John N. ; Krawczynska, Elzbieta G. ; Alazraki, Naomi P. ; Zafari, A. Maziar ; Faber, Tracy L. ; Garcia, Ernest V.
Author_Institution :
Dept. of Radiol., Emory Univ., Atlanta, GA, USA
Volume :
51
Issue :
5
fYear :
2004
Firstpage :
2705
Lastpage :
2712
Abstract :
The quality of a Teboroxime single-photon emission computed tomography (SPECT) study can be degraded by Teboroxime´s rapid myocardial washout and high liver uptake. Described is the use of fast-fanning acquisition and nonlinear regression with distance penalty (NLRDP) to compensate for the two effects. Tl-201/conventional single-rotation Sestamibi (MIBI) and Tl-201/dynamic fast-fanning Teboroxime (TEBO) rest/stress acquisitions were conducted on 18 subjects. TEBO reconstructions were processed by NLRDP using group-averaged kinetics to separate images into liver, myocardium, and background. Reprojections of these compartments were registered with the measured projections. This made possible the extraction of patient-specific kinetics. NLRDP identified defects (abnormal myocardium with different kinetics from normal tissue) by differences in the kinetics of the defect pixels. Enhanced-TEBO (E-TEBO) images were produced by using the kinetic curves to calculate the Teboroxime concentration in each pixel at the time of expected peak myocardial uptake and by omitting the liver compartment. Stress and reversibility total severity scores and total impaired and reversible myocardial mass were computed for the MIBI, TEBO, and E-TEBO images using the Emory Cardiac Toolbox. Regression and correlation analyses of these quantitative indices indicate that Teboroxime SPECT can produce results similar to those of Sestamibi SPECT if E-TEBO images are generated.
Keywords :
cardiology; liver; medical image processing; protocols; regression analysis; single photon emission computed tomography; technetium; Emory Cardiac Toolbox; MIBI; TEBO reconstructions; Tc; Tc-99m Teboroxime; Teboroxime single-photon emission computed tomography; Tl-201/conventional single-rotation Sestamibi; Tl-201/dynamic fast-fanning Teboroxime; correlation analysis; distance penalty; dynamic cardiac SPECT; enhanced-TEBO images; fast-fanning acquisition protocol; group-averaged kinetics; high liver uptake; kinetic curves; nonlinear regression with distance penalty; patient-specific kinetics; rapid myocardial washout; rest/stress acquisitions; reversible myocardial mass; technetium-99m Teboroxime; Computed tomography; Degradation; Image analysis; Image generation; Image reconstruction; Kinetic theory; Liver; Myocardium; Pixel; Stress; Dynamic single-photon emission computed tomography; fast-fanning acquisition; m Teboroxime; nonlinear regression with distance penalty; technetium-;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2004.834813