• DocumentCode
    1139786
  • Title

    A novel method of measurement of synchronous machine losses using synthetic loading

  • Author

    Soltani, Jafar ; Szabados, Barna ; Hoolboom, Jerry

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Isfahan Univ. of Technol., Iran
  • Volume
    51
  • Issue
    6
  • fYear
    2002
  • fDate
    12/1/2002 12:00:00 AM
  • Firstpage
    1228
  • Lastpage
    1233
  • Abstract
    Synthetic loading of synchronous machines can be used to test machines for temperature rise and total losses without the need for attaching mechanical load to the shaft. A new phase modulation technique of the voltage is proposed in lieu of the traditional dual-frequency method that suffers from cumbersome equipment and also predicts higher losses. A simple bang-bang DC switch is used to modulate the excitation current of an induction generator. System modeling was performed using the traditional two-axis method, and has proven that the method is feasible. Practical test results are shown to validate the simulated performance. It is shown that the only constraint of this synthetic loading is to maintain the RMS values of the current and voltage at rated values.
  • Keywords
    loss measurement; machine testing; machine theory; phase modulation; synchronous machines; bang-bang DC switch; excitation current modulation; synchronous machine losses measurement; synthetic loading; temperature rise; total losses; voltage phase modulation technique; Induction generators; Joining processes; Loss measurement; Phase modulation; Shafts; Switches; Synchronous machines; Temperature; Testing; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2002.808055
  • Filename