Title : 
Error Reduction in HF Loop DF Systems
         
        
            Author : 
Jenkins, Herndon H. ; Moss, Richard W. ; Scott, Lawrence
         
        
            Author_Institution : 
Engineering Experiment Station Georgia Institute of Technology Atlanta, Ga.
         
        
        
        
            fDate : 
5/1/1969 12:00:00 AM
         
        
        
        
            Abstract : 
Techniques for reducing bearing errors in vertical loop HF direction finders for ionospherically propagated signals were evaluated in a dual-channel system. A main channel provides a bearing display from the output of a rotating loop; an auxiliary channel unblanks the bearing ng display when propagation conditions are favorable for minimum bearing error. Circuitry to provide optimum unblanking for a wide variety of signal and fade conditions is described. The results of an operational evaluation are presented and show that a large majority of the unblanked bearings can be restricted to ±15° of the great-circle bearing with average bearing errors of 10° or less. Operational comparison with a contemporary system shows that the dual-channel system performance is superior with a 2 to 1 reduction ion in bearing spreads, standard deviations, and RMS error.
         
        
            Keywords : 
Circuits; Displays; Error correction; Hafnium; Interference; Ionosphere; Navigation; Polarization; System performance; Voltage;
         
        
        
            Journal_Title : 
Aerospace and Electronic Systems, IEEE Transactions on
         
        
        
        
        
            DOI : 
10.1109/TAES.1969.309851